Technology Center
There is no compromise on safety!
SECULOCK's reliability test
that exceeds Customer’s expectation
SECULOCK is a specialized company that is equipped with
a comprehensive and specialized security technology
in programing, designing, electronic circuits, Mortise, and production.
Mortise, Handle durability Test
The strength of the door lock and the stability of the handle are tested with rigorous standards.
Test items | our standards | KS/KC safety standards | |
---|---|---|---|
Deadbolt | push | 1,764N | 1,470N |
lateral pressure | 2,941N | 2,451N | |
Handle | tensile load | It should withstand the force of 2,696 N working normally and should be able to withstand the opening force from outside up to 5,000 N even if it is deformed or damaged. | It should withstand the force of 2,451 N working normally and should be able to withstand the opening force from outside up to 5,000 N even if it is deformed or damaged. |
vertical load |
Open/Close Repeatability Test
Tests are conducted to reinforce the durability of various moving parts (button keys, chip keys, handles).
Test items | our standards | KS/KC safety standards | |
---|---|---|---|
Outer body | Button key operation test |
30,000 times | 20,000 times |
RF key operation test |
50,000 times | 40,000 times | |
Inner body | Inner body handle operation test |
50,000 times | 40,000 times |
Total | 130,000 times | 100,000 times |
High Temperature∙Humidity Test / Low Temperature Test
In consideration of the user's various environments (high temperature, high humidity, low temperature), tests are conducted to ensure that the product does work normally in those various user environments.
Test items | our standards | KS/KC safety standards |
---|---|---|
high temperature | When taking it out after exposure for 48 hours at 80±2°C, it should start working normally within 5 minutes at room temperature. | When taking it out after exposure for 48 hours at 70±2°C, it should start working normally within 5 minutes at room temperature. |
high humidity | When taking it out after exposure for 48 hours at the temperature 70±3°c / humidity 95%+2/-3, it should start working normally within 5 minutes at room temperature. | When taking it out after exposure for 48 hours at the temperature 60±3°c / humidity 95%+2/-3, it should start working normally within 5 minutes at room temperature. |
low temperature | When taking it out after exposure for 48 hours at -30±2°C, it should start working normally within 5 minutes at room temperature | When taking it out after exposure for 48 hours at -25±2°C, it should start working normally within 5 minutes at room temperature |
Salt Water Spray Test
In consideration of the user's various environments (seaside, and other salts), tests are conducted to ensure that the product does work normally in those various user environments.
Test items | standards |
---|---|
Salt concentration | 5%±0.5% |
Chamber temperature | 35°c±2°c |
Spray pressure | 1.02 ~ 2.24 kg/cm² |
Spray volume | 1.0 ~ 2.0㎖ / 80 cm²/hr |
Test time | 72hr |
Electric Shock Test
Tests are conducted with strict numerical values using a circuit that does not allow for the door opening by static electricity and electric shock.
Test items | our standards | KS/KC safety standards |
---|---|---|
Static electricity test | Repeating discharges 20 times per second in operation (at least 20 times of single discharge) 1 metal part-contact ±8.8 kV 1 non-metallic part – non-contact ±16.6 kV There should be no malfunction or loss of function in the tests for certifications. | Repeating discharges 20 times per second in operation (at least 10 times of single discharge) 1 metal part-contact ±8 kV 1 non-metallic part – non-contact ±15 kV There should be no malfunction or loss of function in the tests for certifications. |
Electric shock test | 200 times (20 seconds) continuously at 10Hz cycle in the outside device of the product while the door is in a locked state 3 metal part-contact ±27.5 kV 3 non-metallic part – non-contact ±33 kV There should be no locking release in the tests for certifications. | 200 times (20 seconds) continuously at 10Hz cycle in the outside device of the product while the door is in a locked state 3 metal part-contact ±25 kV 3 non-metallic part – non-contact ±30 kV There should be no locking release in the tests for certifications. |
External Impact Test
In preparation for mechanical and physical shocks from the outside, drop and external strength tests are conducted.
Test items | our standards | KS/KC safety standards |
---|---|---|
Drop test | There should be no problem in the function of the product after applying impact to the outer surface by free-falling from a height of 1.3m with a 540g steel ball. | There should be no problem in the function of the product after applying impact to the outer surface by free-falling from a height of 1.3m with a 540g steel ball. |